ARK-135 12A ESC
1. Designed to offer high power and high efficiency combined with low weight and compact dimensions.
2. Automatic cut- off and auto detection of all types and number of cells.
3. Brake set to non-active-Factory default setting
It is defined as a hard start mode. Start motor quickly and be able to response to acceleration instantly. It takes the least time for motor to reach its full speed. This mode is suitable for these models, such as helicopter, which require fast response to acceleration. Under this mode, at the termination of a powered flight, the controllers will reduce the current drain to the motor progressively so providing ample power to the BEC, receiver for positive control. There is no immediate cut off but a rather drizzle down of propeller speed and motor response. The player will not lose the power at one moment. The system will provide a very good soft landing before the cut off of the system power.
4. Brake set to active
It is defined a soft star mode. Start slowly and steadily, without any intermittence at full speed with a very solid brake reaction when actuated.
5. Over temperature protection
Motor to be intermittently turned off when the temperature reaches 105° centigrade.
6. Low speed control
Be able to let motor running steadily at very low speed.
7. Fail safe mode
Once there is any abnormal signal or signal fail between transmitter and receiver being detected for about 2 seconds, the controller will cut off the motor power automatically. Once the signals get back to normal, the system will auto-turn on again automatically.